Missed Check-in (primary volume alarm)

Success conditions (resolve/close):

  • Worker checks in following call-out; or
  • Worker is confirmed OK but cannot check in (acknowledge with reason); or
  • Emergency contact confirms responsibility and acknowledges, with a clear plan.

Procedure:

  1. Open Worker Details immediately.
  2. Review:
    • Last check-in time
    • Check-in frequency
    • Time overdue
    • Location last updated time
  3. Call Attempt #1 (≤ 1 minute from trigger)
  4. Send message (before Attempt #2)
  5. Wait 5 minutes
  6. Call Attempt #2
  7. ERP emergency contacts → wait 15 → retry once
  8. Personal contacts (if provided)
  9. Emergency services (welfare check as required)

Shift Panic (highest severity)

Principle: Panic is urgent until proven otherwise.

IMPORTANT: IF users are connected via GPS, Garmin Response center or Global Rescue (Zoleo) will be responding to the user directly, and coordinating with emergency services. Do not escalate to emergency response if the user is connected by GPS communicator.

Procedure:

  1. Request Location immediately (if stale)
  2. Operator #1 owns the incident. Calls user in Panic. If no answer, immediately initiate call #2.
  3. Dual escalation:
    • Operator #1 calls emergency services immediately. Relay the context of the call and location to 911 dispatch. May require transfer to local emergency dispatch.
    • Operator #2 continues escalation to emergency contacts until acknowledged.
  4. Advise Emergency Contact of steps being taken. If emergency contact states that response is being handled internally, stand down and relay to the emergency dispatcher.
  5. Do not de-escalate based on assumptions. De-escalate only on confirmed information.